| Parameter | Value |
|---|---|
| UV peak wavelength | 365nm |
| IR peak wavelength | 940nm |
| Visible light | 380nm-760nm full wavelength, in line with CIE photopic luminosity function |
| Resolution | 0.1% |
| Measurement accuracy | better than ± 2% (colorless and uniform transparent material) |
| Maximum sample thickness | <8mm |
| Weight | About 165 g (batteries excluded) |
| Display | Segment LCD |
| Dimension | 120mm × 25mm × 75mm |
| Power supply | 4 AAA alkaline dry batteries |
LS162 solar film transmission meter appearanceFeature
![]()
Packing
| No. | Description | Quantity | Unit |
|---|---|---|---|
| 1 | LS162 Transmission Meter | 1 | pcs |
| 2 | AAA battery | 4 | pcs |
| 3 | User Manual | 1 | pcs |
| 4 | Certificate/warranty card | 1 | pcs |
| 5 | Packing box dimension 18*11*5 cm(L*W*H) | 1 | pcs |

1. The difference between LS162 (940nm) and LS162A (1400nm) window film transmission meters
The main difference between LS162 and LS162A is that the IR bands are different. The infrared peak wavelength of LS162 is 940nm and the LS162A is 1400nm. These two bands are more representative bands. The absorbing film has a better infrared rejection effect at 940nm.The metallic film (Insulation by reflection) has a better infrared rejection effect at 1400nm. Please choose the appropriate instrument according to your own film.
2. The difference between LS162 and LS163 window film transmission meters
LS162 measuring notch width is 8mm, LS163 measuring notch width is 6mm;
LS162 use point light source, while LS163 use parallel light path. The latter has higher data accuracy when measuring thick materials;
LS162 can only measure visible light transmittance, infrared and ultraviolet rejection rate, while LS163 can measure infrared and ultraviolet transmittance in addition to these three data;
LS163 has three display interfaces, the screen can be rotated in four directions and has a screen backlight, but LS162 does not.
3. The difference between LS162 and LS101 window film transmission meters
LS162 use point light source, while LS101 use parallel light path. The latter has higher data accuracy for measuring thick materials;
LS162 can only be powered by battery, while LS101 can also be powered by USB cable in addition to battery;
LS101 has screen backlight, while LS162 has no screen backlight;
Except for the above differences and the differences in appearance, the other parameters of LS101 and LS162 are completely the same.